Product Description for True RMS current clamp BE42
Non-contact DC and AC voltage measurement and AC current measurement with maximum precision
The compact BE42 true RMS current clamp with integrated flashlight function enables particularly precise measurements of the true in industrial and building technology systems or even in confined control or confined control cabinets - without having to interrupt the circuit. having to interrupt the circuit. The current strength is determined completely contact-free by measuring the electromagnetic field. Cable connections do not have to be disconnected or interrupted. This makes testing and maintenance work particularly efficient. Thanks to the battery-saving function "Auto-Power-Off", the device switches off fully automatically when not in use. fully automatically when not in use.
Ideal for:
- Service technicians for trouble-free maintenance of machines and systems
- Craftsmen and electricians working in confined switch cabinets, in building services and for building maintenance
Professional equipment for all common measuring methods
With its professional full equipment and functionality, the BE42 clamp ammeter leaves almost nothing to be desired and surpasses conventional conventional multimeters by far. The all-round current measuring instrument is suitable for measuring direct and alternating alternating voltage, alternating current, resistance and continuity testing of circuits, fuses and contacts. In addition, the clamp The clamp ammeter also impresses with convenient functions that make work easier, such as a such as a HOLD function, MAX display, battery status display, warning warning when the measuring range is exceeded and practical LED lighting
Practical one-handed operation
All measurement results are clearly displayed on the backlit
.
LCD display. The measuring method is selected conveniently and easily easily via a practical rotary switch.
Combines ergonomics and precision in top form
Where other measuring devices have to fit due to limited space and visibility design, the compact and ergonomically optimized current clamp shows its true optimized BE42 current clamp shows its true size. All display and and operating elements, as well as the slim, wide-opening clamp and the opening lever, are designed for comfortable one-handed operation. one-handed operation. An all-round anti-shock rubber coating makes the BE42 current clamp, which is dust-protected to IP40, is particularly easy to grip, reliably protects them from knocks and damage and also prevents also prevents unintentional slipping when placed on non-horizontal surfaces.
Features and technical specifications
Play it safe when measuring electrical currents and voltages.
safely. The BE42 true RMS current clamp combines maximum safety and functionality
functionality at an attractive price. Designed for high currents
up to 400 A, the measuring device fulfills all safety requirements of the
measuring category CAT III 600 V.
Max. Cable cross-section: 28 mm
LC display: backlit
LCD display: 4-digit (max. display 9999)
Dimensions: 210 x 75 x 35 mm
Weight: 285 gDirect voltage
Measuring range: 0.2 to 600 V
Accuracy ±[%] (0.2 V): ±(0.8 % +4)
Accuracy ±[%] (2 V/20 V/200 V): ±(1.5 % +2)
Accuracy ±[%] (600 V): ±(2 % +2)
AC voltage (V/AC)
Measuring range: 2 to 600 V
Accuracy ±[%] (2 V/20 V/200 V): ±(1.8 % +8)
Accuracy ±[%] (600 V): ±(2.5 % +8)
Alternating current (A/AC)
Measuring range: 2 to 400A
Accuracy ±[%] (2 A): ±(2.5 % +10)
Accuracy ±[%] (20 A): ±(2.5 % +4)
Accuracy ±[%] (200 A): ±(2.5 % +4)
Accuracy ±[%] (400 A): ±(3 % +6)
Resistance (Ohm)
Measuring range: 0 - 20 MΩ
Accuracy ±[%] (200 Ω): ±(1.0 % +4 digits in the 200 Ω measuring range)
Accuracy ±[%] (200 Ω/2 kΩ/20 kΩ): ±(1.5 % +2)
Accuracy ±[%] (2 MΩ): ±(2.5 % +3)
Accuracy ±[%] (20 MΩ): ±(3,5 % +5)
Integrated flashlight function
Scope of delivery:
- Hand-held measuring device BE42
- Safety leads with test probes (2x)
- Operating instructions
Difference between conventional measuring devices and measuring devices with true RMS function
A digital measuring device without true RMS function assumes that the measured AC assumes that the measured AC signal is sinusoidal and calculates the measured raw measured raw signal for the display. In reality, however, the However, in reality the current flow is never purely sinusoidal; consumers such as switching power supplies, speed or power regulators etc. cause which in turn cause distorted current curves. As these are no longer purely sinusoidal, they cannot be measured correctly without the True RMS function.
True RMS measuring devices can also
measure
non-sinusoidal
signal curves correctlyand
are thereforenon-sinusoidal signal characteristics and are therefore able to measure the true rms value of any alternating variable directly. The True Root Mean Square" (which translates as "true root mean square") square averaging) stands for the correct determination and output of the true of the true effective value.
Practical advantages:
- 4-digit LCD display (max. display 9999)
- Robust housing with molded rubber protection
- CAT III 600 V
- AC current measurement up to 400 A
- AC voltage measurement up to 600 V
- DC voltage measurement up to 600 V
- True RMS function: precise measurement through direct determination of the true RMS value
- Resistance measurement
- Continuity test and diode test
- Automatic and manual range selection
- Measured value hold function and maximum value display
- Display illumination
- Suitable for wire diameters up to 28 mm
- Battery-saving automatic switch-off function
- Integrated LED lamp for optimum illumination of the working area
- Dust-protected: Protection class IP40
- Battery status display
Safety information and warnings are provided in the device instructions
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.205.242 | |
DC voltage [V/DC] | ||
Min. measuring range | DC voltage [V] | 0.2 | |
Max. measuring range | DC voltage [V] | 600 | |
Accuracy ± [%] (0.2 V) | DC voltage [V/DC] | ±(0,8 % +4) | |
Accuracy ± [%] (2 V / 20 V / 200 V) | DC voltage [V/DC] | ±(1,5 % +2) | |
Accuracy ± [%] (600 V) | DC voltage [V/DC] | ±(2 % +2) | |
AC voltage [V/AC] | ||
Min. measuring range | AC voltage [V] | 2 | |
Max. measuring range | AC voltage [V] | 600 | |
Accuracy [%] ± (2 V / 20 V / 200 V) | AC voltage [V/AC] | ±(1,8 % +8) | |
Accuracy [%] (600 V) | AC voltage [V/AC] | ±(2,5 % +8) | |
Alternating current [A/AC] | ||
Min. measuring range | Alternating current [A] | 2 | |
Max. measuring range | Alternating current [A] | 400 | |
Accuracy ± [%] (2 A) | alternating current [A/AC] | ±(2,5 % +10) | |
Accuracy ± [%] (20 A) | alternating current [A/AC] | ±(2,5 % +4) | |
Accuracy ± [%] (200 A) | alternating current [A/AC] | ±(2,5 % +4) | |
Accuracy ± [%] (400 A) | alternating current [A/AC] | ±(3 % +6) | |
Resistance [Ω] | ||
Min. measuring range [Ω] | Resistance | 200 | |
Max. measuring range [Ω] | resistance | 20 | |
Accuracy ±[%] (200 Ω) | resistance [ohm] | ±(1,0 % +4) | |
Accuracy ± [%] (200 Ω/2 kΩ/20 kΩ) | resistance [ohm] | ±(1,5 % +2) | |
Accuracy ± [%] (2 MΩ) | resistance [ohm] | ±(2,5 % +3) | |
Accuracy ± [%] (20 MΩ) | resistance [ohm] | ±(3,5 % +5) | |
Display | ||
Counts | 2,000 | |
Measurement rate | ||
Measurement rate | 2 Hz | |
Housing design | ||
Plastics | ||
Interfaces | ||
Connection sockets for 4 mm safety connectors (banana) | ||
Measuring category | ||
CAT III (600 V) | ||
Safety | ||
EN 61010-1 | ||
Degree of pollution 2 | ||
Type of protection | ||
IP40 | ||
Power supply | ||
Internal (battery) | ||
Ambient conditions | ||
Operation - min. temperature [°C] | 5 | |
Operation - max. temperature [°C] | 40 | |
Dimensions | ||
Length (packaging excluded) [mm] | 210 | |
Width (packaging excluded) [mm] | 75 | |
Height (packaging excluded) [mm] | 35 | |
Diameter (lamp diameter opening) [mm] | 28 | |
Weight | ||
(packaging excluded) [kg] | 0.285 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Measuring device | ||
Safety measuring lines with test probes | ||
Operating manual |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
AC voltage [V/AC] | ||
DC voltage [V/DC] | ||
Resistance [Ω] | ||
Alternating current [A/AC] | ||
Functions and features | ||
Maximum value display | ||
Measured value hold function | ||
Alternating current | ||
DC voltage | ||
AC voltage | ||
Resistance | ||
Automatic measuring range selection | ||
Integrated torch | ||
Automatic switch-off | ||
Backlit display | ||
Indication when exceeding the measuring range | ||
Diode testing | ||
Continuity test | ||
Battery status indication |
standard equipment
optionally available
not available
Similar products
Why you can trust Trotec
As one of the leading international manufacturers of air treatment solutions, Trotec offers industrial and commercial customers innovative products for air purification, dehumidification, heating, air conditioning and ventilation. For our high-performance devices, we rely 100 % on research, development, design and production in Germany. For the highest quality standards, sophisticated system solutions and fresh ideas.