Product Description for Moisture Meter BM40
Anyone who wants to measure moisture quickly or, above all, non-destructively in materials such as wood or mineral building materials or wants to monitor the drying process will find his reliable partner in the BM40. Simply place the measuring electrodes of the device on the material to be tested.
Moisture measurement is absolutely non-destructive via capacitive sensors using the dielectric measuring method, since no electrodes or probes need to be introduced into the material to be measured. For increased accuracy of the readings given directly in% by weight, correction factors are available for the different types of material.
The ready-to-use BM40 convinces during the measurement due to its easy handling and fast reaction times.
An ambient temperature measurement, the battery status display and the energy-saving auto-off function complete the versatile scope of performance.
Benefits in practice:
- Development, design, manufacturing: 100 % Trotec
- Fast and non-destructive measurement of moisture in mineral building materials and wood
- 10 adjustable material curves for the most important building materials and types of wood
- Incl. ambient temperature measurement
- Easy operation with just one button
- Direct measured value display in %
- Battery status display
- Automatic shutdown
- Practically optimized German industrial design – protected design
Here are some technical details of the BM40 at a glance:
- Electrode length: approx. 40 mm
- Measuring principle: dielectric
- Working ambient conditions: -10 to +50 °C / max. 85 % r.H
- Storage ambient conditions: -10 to +55 °C
- Penetration depth: 0 - 50 mm, non-destructive
- Power supply: 9 V battery
- Dimension L x W x H (in mm): 168 x 35 x 75
- Weight: 220 g
Solid brick
- Measuring range: 0,2 to 15 %
- Accuracy: < 2 %
Anhydrite screed
- Measuring range: approx. 0,2 to 12 %
- Accuracy: < 2%
Cement screed
- Measuring range: 0,1 to 15 %
- Accuracy: < 2%
Lime sandstone
- Measuring range: 0,1 to 20 %
- Accuracy: < 2%
Cellular concrete
- Measuring range: 6 to 23 %
- Accuracy: < 2% (at measured value >8%)
Hollow brick (high insulation)
- Measuring range: 0,4 to 15 %
- Accuracy: < 3%
Concrete
- Measuring range: 0,1 to 13 %
- Accuracy: < 3%
Hardwood
- Measuring range: 1 to 50 %
- Accuracy: < 5% (at measured value >9%)
Softwood
- Measuring range: 4 to 51 %
- Accuracy: < 5% (at measured value >9%)
Particle board
- Measuring range: 4 to 50 %
- Accuracy: < 5% (at measured value >9%)
Resolution
- Wood: 0,1 %
- Mineral building material: 0,1 %
Measured rate
Scope of delivery: measuring device, instruction manual
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.205.035 | |
Measuring principle | ||
Electrode length [mm] | 40 | |
Min. penetration depth (non-destructive) [mm] | 0 | |
Max. penetration depth (non-destructive) [mm] | 50 | |
Solid brick | ||
Min. measuring range | solid brick [%] | 0 | |
Messbereich max. [%] | 20 | |
Accuracy [%] | brick | < 2 | |
Anhydrite screed | ||
Min. measuring range | anhydrite screed [%] | 0 | |
Max. measuring range | anhydrite screed [%] | 20 | |
Accuracy [%] | anhydrite screed | < 2 | |
Cement screed | ||
Min. measuring range | cement screed [%] | 0 | |
Max. measuring range | cement screed [%] | 20 | |
Accuracy [%] | cement screed | < 2 | |
Sand-lime brick | ||
Min. measuring range | sand-lime brick [%] | 0 | |
Max. measuring range | sand-lime brick [%] | 20 | |
Accuracy [%] | sand-lime brick | < 2 | |
Gas concrete | ||
Min. measuring range | gas concrete [%] | 0 | |
Max. measuring range | gas concrete [%] | 20 | |
Accuracy [%] | gas concrete | <2 (with measured value > 8 %) | |
High-insulating brick | ||
Min. measuring range | high-insulating brick [%] | 0 | |
Max. measuring range | high-insulating brick [%] | 20 | |
Accuracy [%] | high-insulating brick | < 3 | |
Concrete | ||
Min. measuring range | concrete [%] | 0 | |
Max. measuring range | concrete [%] | 20 | |
Accuracy [%] | concrete | < 3 | |
Hardwood | ||
Min. measuring range | hardwood [%] | 0 | |
Max. measuring range | hardwood [%] | 50 | |
Accuracy [%] | hardwood | <5 (with measured value > 9 %) | |
Softwood | ||
Min. measuring range | softwood [%] | 0 | |
Max. measuring range | softwood [%] | 50 | |
Accuracy [%] | softwood | <5 (with measured value > 9 %) | |
Chipboard | ||
Min. measuring range | chipboard [%] | 0 | |
Max. measuring range | chipboard [%] | 50 | |
Accuracy [%] | chipboard | <5 (with measured value > 9 %) | |
Temperature | ||
Min. temperature [°C] | -10 | |
Max. temperature [°C] | 55 | |
Accuracy - Approx. temperature ± [°C] | 2 | |
Resolution [°C] | 1 | |
Resolution | ||
Wood [%] | 0.1 | |
Mineral building materials [%] | 0.1 | |
Measurement rate | ||
Material moisture | 0.5 s | |
Device control | ||
Membrane keyboard | ||
Display | ||
LCD | ||
Monochrome | ||
Housing design | ||
Plastics | ||
Ambient conditions | ||
Operation - min. temperature [°C] | -5 | |
Operation - max. temperature [°C] | 50 | |
Operation - max. relative humidity [% RH] | 85 | |
Storage - min. temperature [°C] | -10 | |
Storage - max. temperature [°C] | 55 | |
Power supply | ||
Internal (battery) | ||
Internal (battery) | 1 x 9 V battery | |
Dimensions | ||
Length (packaging excluded) [mm] | 168 | |
Width (packaging excluded) [mm] | 35 | |
Height (packaging excluded) [mm] | 75 | |
Weight | ||
(packaging excluded) [kg] | 0.22 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Measuring device | ||
Operating manual |
Ascertainable measured values and functions | ||
---|---|---|
Functions and features | ||
Automatic switch-off | ||
Non-destructive measurement method | ||
Battery status indication | ||
Material selection |
standard equipment
optionally available
not available
Downloads
Declaration of conformity for Moisture measuring device BM40 (DE)
TRT-CE-BM40-HS-001-DE.pdf (109 KB)
Declaration of conformity for Moisture measuring device BM40 (INT)
TRT-CE-BM40-HS-001-EN.pdf (109 KB)
Operating manual for Moisture measuring device BM40 (DA)
TRT-BA-BM40-TC-006-DA.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (DE)
TRT-BA-BM40-TC-006-DE.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (EN)
TRT-BA-BM40-TC-006-EN.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (ES)
TRT-BA-BM40-TC-006-ES.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (FI)
TRT-BA-BM40-TC-006-FI.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (FR)
TRT-BA-BM40-TC-006-FR.pdf (1.02 MB)
Operating manual for Moisture measuring device BM40 (HU)
TRT-BA-BM40-TC-006-HU.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (IT)
TRT-BA-BM40-TC-006-IT.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (NL)
TRT-BA-BM40-TC-006-NL.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (NO)
TRT-BA-BM40-TC-006-NO.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (PL)
TRT-BA-BM40-TC-006-PL.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (PT)
TRT-BA-BM40-TC-006-PT.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (RU)
TRT-BA-BM40-TC-006-RU.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (SV)
TRT-BA-BM40-TC-006-SV.pdf (0.99 MB)
Operating manual for Moisture measuring device BM40 (TR)
TRT-BA-BM40-TC-006-TR.pdf (0.99 MB)
Similar products
Why you can trust Trotec
As one of the leading international manufacturers of air treatment solutions, Trotec offers industrial and commercial customers innovative products for air purification, dehumidification, heating, air conditioning and ventilation. For our high-performance devices, we rely 100 % on research, development, design and production in Germany. For the highest quality standards, sophisticated system solutions and fresh ideas.
People. Technology. Product.
What we do, we do with passion. And with real conviction. We are always there when it comes to climate. Find out more in our video.