TDS 20 R Electric Fan Heater + Pro extension cable 20 m / 230 V / 2.5 mm²
Availability: Available again from week 49
TDS 20 R Electric Fan Heater
Everywhere a condensation-free warmth without long air transport routes is needed with immediate effect, the inexpensive TDS-R electric fan heaters are the optimal choice.
Everywhere a condensation-free warmth without long air transport routes is needed with immediate effect, the inexpensive TDS-R electric fan heaters are the optimal choice.
Because in comparision to direct fired gas or oil heaters don't consume oxygen and produce no combustion gases, they are well suited for temperature management of unheated inside rooms, workshops or garages.
Thanks to the integrated thermostat control the produced warm air flow can be adjusted continuously to the desired temperature. The thermostat controlled heating elements of the TDS 20 R switch on the permanent fan, if needed.
Benefits in pratice:
- Integrated room thermostat for constant, cosy warmth
- Overheat protection
- Fan motor with thermal protection
- Condensation-free heating - no oxygen consumption - because of that the TDS 20 R is suitable for uses in enclosed rooms.
- Easy to transport and use
- Fan operation is also possible without heating function
Fields of application:
- Automobile workshops
- Construction sites
- Assembly applications
- Gastronomy
- Storerooms and workshops
- Greenhouses
- and counting...
Technical data:
- Heating performance max.: 3 kW / 2,580 kcal
- Air flow rate: 305 m³/h
- Power: 13 A
- Mains voltage: 230 V / 50 Hz
- Power connector: Schuko-plug / CEE 7/7
- Connection cable: integrated (length 1.5m)
- Thermostat: integrated
- Mobility: portable
- Noise level dB (A): 46
- Overheat protect: existing
- Protection type: IP44
- Length: 250 mm
- Width: 245 mm
- Height: 315 mm
- Weight: 4.7 kg
Pro-extension cable 20 m / 230 V / 2.5 mm² - Made in Germany
This extremely robust 230 volts extension cable is in every way Trotec high quality. The yellow cable sheath provides a reliable protection on every construction site and the imprinted Trotec logo lets you recognize the cable always and everywhere - for a better theft protection! But not only the external appearance of the cable is convincing: the high-quality product "made in Germany" with protection class IP44 it is carefully processed as well. No product made in China or from the construction market! The oil-resistant and acid-resistant neoprene rubber meets the BG requirements for construction sites and is suitable for ambient temperatures from -25 °C to +60 °C.
Technical data:
- Length: 20 m
- Supply voltage: 230 V
- Cross section: 2.5 mm²
- Plug / Socket: CEE 7/7 16 A
Technical data | ||
---|---|---|
General information | ||
Article number | 1.410.000.002 | |
Heating capacity | ||
Level 1 [kW] | 0 | |
Level 2 [kW] | 1.5 | |
Level 3 [kW] | 3 | |
Level 4 [kW] | ||
Level Max. [kcal] | 2,580 | |
Air flow rate | ||
Level Max. [m³/h] | 411 | |
Temperature increase | ||
in [°C] | 79 | |
Operating range | ||
Min. temperature [°C] | -20 | |
Max. temperature [°C] | 45 | |
Fans | ||
axial | ||
Number of fan stages | 1 | |
Electrical values | ||
Mains connection | 230 V, 50 Hz | |
Nominal current consumption [A] | 13.04 | |
Recommended fusing [A] | 16 | |
Power input [kW] | 3 | |
Electric connection | ||
Connection plug | CEE 7/7 | |
Provided by the customer | ||
Cable length [m] | 1.37 | |
Functions and features | ||
Auto restart function | ||
Sound values | ||
Distance 1 m [dB(A)] | 53 | |
Hose connection | ||
Hose connection | ||
Dimensions | ||
Length (packaging excluded) [mm] | 210 | |
Width (packaging excluded) [mm] | 195 | |
Height (packaging excluded) [mm] | 270 | |
Weight | ||
(packaging excluded) [kg] | 3 |
Equipment, features and functions | ||
---|---|---|
Operation | ||
Thermostat | ||
Mobility | ||
Carry/transport handle(s) | ||
Housing design | ||
Metal |
standard equipment
optionally available
not available
Technical data | ||
---|---|---|
General information | ||
Article number | 7.333.000.376 | |
Cable specification | ||
Length [m] | 20 | |
Cross-section [mm²] | 2.5 | |
Number of strands | 3 | |
Type | H07RN-F | |
Plug and coupling | ||
Connection plug | CEE 7/7 | |
Electrical data | ||
Input voltage [V] | 230 | |
Nominal current consumption [A] | 16 | |
Type of protection | IP 44 | |
Ambient conditions | ||
Min. temperature range [°C] | -25 | |
Max. temperature range [°C] | 60 | |
Equipment | ||
Solid rubber plug and coupling | ||
Safety contact coupling with sealing cap |
standard equipment
optionally available
not available

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (CS)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-CS.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (DA)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-DA.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (DE)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-DE.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (EN)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-EN.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (ES)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-ES.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (ET)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-ET.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (FI)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-FI.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (FR)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-FR.pdf (1.82 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (HR)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-HR.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (IT)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-IT.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (LT)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-LT.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (LV)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-LV.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (NL)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-NL.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (NO)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-NO.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (PL)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-PL.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (PT)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-PT.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (RO)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-RO.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (RU)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-RU.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (SV)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-SV.pdf (1.78 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (TR)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-TR.pdf (1.79 MB)

Operating manual for electrical fan heater TDS 20 R / 30 R / 50 R (UK)
TRT-BA-TDS-20R-TDS-30R-TDS-50R-TC-011-UK.pdf (1.79 MB)