TDS 20 Electric Fan Heater + Wall and Ceiling Bracket
Availability: Immediately available
TDS 20 + Wall and Ceiling Bracket
The TDS 20 electric heater provides a heating performance between 1.65 kW and 3 kW in 3 stages. In additional to this, you will get a wall and ceiling bracket!
In comparison to direct fired gas or oil heaters, the electric fan heaters of the TDS series don't consume oxygen and produce combustion gases. Because of that this devices can be used everywhere, especially for temperature controls unheated interiors.
The possibility for wall mounting or installation under the ceiling open wide range of application possibilities, e.g. for heating of building container, marketplaces, greenhouses, small storages, garages, workshops, boathouses or at installation applications.
Thanks to the integrated thermostat control, the produced warm air flow can be adjusted continuously to the desired temperature at all TDS models.
The TDS electric heaters (excepting TDS 10) can be used in the fan mode without the heating function and they have an ideal temperature control via multistage performance control for demand-based dosing of heating power.
Benefits in pratice:
- 100% TROTEC - development, design, production
- Multistage temperature control with up to 3 heating stages
- Integrated room thermostat for constant, cosy warmth
- Overheat protection
- 10% more power than competitive models
- Fan motor with thermal protection
- Condensation-free heating - no oxygen consumption - because of that the TDS 20 is suitable for uses in enclosed rooms
- Standard built-in air baffle for optimization of heat dissipation (guarantees maximum efficiency)
- Fan function
Fields of application:
- Building container
- Garages
- Gastronomy
- Greenhouses
- Marketplaces
- Storerooms and workshops
- Boathouses
- Workshops
- Shipbuilding
- and counting...
Technical data:
- Heating performance stage 1: only fan
- Heating performance stage 2: 1.65 kW
- Heating performance stage 3: 3.3 kW (max. 2,838 kcal)
- Air flow rate: 335 m³/h
- Blower stages: 1
- Power: 14.3 A
- Mains voltage: 230 V / 50 Hz
- Power connector: Schuko-plug / CEE 7/7
- Connection cable: integrated (length 1.5m)
- Thermostat: integrated
- Mobility: portable
- Noise level: 46 dB (A)
- Overheat protect: existing
- Protection type: IPX4
- Length: 255 mm
- Width: 265 mm
- Height: 395 mm
- Weight: 5.3 kg
Information: At the back of the electric heaters (cold) air is being sucked in, heated up and exhausted as warmed air again. Thereby, the room temperature increases constantly over time. Because very much air is being transported the exhausted air doesn't feel very hot! Due to the high air flow rate the whole room is warmed up gradually.
TDS 10 / TDS 20 Wall and Ceiling Bracket
Use the wall and ceilig bracket for the TDS 10 and TDS 20 for making space and for keeping away the electric heater from unauthorized people. High mounted on the wall or on the ceiling, the electric heater will disappear not only from your field of view and work area, but also out of the reach of unauthorized persons.
Caution: please note that the mounting bolts are not include in the scope of delivery!
Technical data | ||
---|---|---|
General information | ||
Article number | 1.410.000.015 | |
Heating capacity | ||
Level 1 [kW] | 0 | |
Level 2 [kW] | 1.65 | |
Level 3 [kW] | 3.3 | |
Level Max. [kW] | 3.3 | |
Air flow rate | ||
Level Max. [m³/h] | 335 | |
Temperature increase | ||
in [°C] | 85 | |
Operating range | ||
Min. temperature [°C] | -20 | |
Max. temperature [°C] | 45 | |
Fans | ||
axial | ||
Number of fan stages | 1 | |
Electrical values | ||
Mains connection | 230 V, 50 Hz | |
Nominal current consumption [A] | 14.4 | |
Recommended fusing [A] | 16 | |
Power input [kW] | 3.3 | |
Electric connection | ||
Connection plug | CEE 7/7 | |
Provided by the customer | ||
Cable length [m] | 1.35 | |
Functions and features | ||
Auto restart function | ||
Sound values | ||
Distance 1 m [dB(A)] | 46 | |
Dimensions | ||
Length (packaging excluded) [mm] | 265 | |
Width (packaging excluded) [mm] | 255 | |
Height (packaging excluded) [mm] | 395 | |
Weight | ||
(packaging excluded) [kg] | 5 |
Equipment, features and functions | ||
---|---|---|
Mobility | ||
Carry/transport handle(s) | ||
Ceiling holder | ||
Wall holder | ||
Housing design | ||
Metal |
standard equipment
optionally available
not available
Technical data | ||
---|---|---|
General information | ||
Article number | 6.100.007.022 |
standard equipment
optionally available
not available

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (CS)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-CS.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (DA)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-DA.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (DE)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-012-DE.pdf (2.53 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (EN)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-012-EN.pdf (2.52 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (ES)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-ES.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (ET)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-ET.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (FI)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-FI.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (FR)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-012-FR.pdf (2.56 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (HR)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-HR.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (IT)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-IT.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (LT)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-LT.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (LV)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-LV.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (NL)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-NL.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (NO)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-NO.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (PL)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-PL.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (PT)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-PT.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (RO)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-RO.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (RU)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-RU.pdf (2.44 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (SV)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-SV.pdf (2.43 MB)

Operating manual for electric heating device TDS 10 / TDS 20 / TDS 30 / TDS 50 (TR)
TRT-BA-TDS10-TDS20-TDS-30-TDS-50-TC-011-TR.pdf (2.43 MB)