Convector TCH 22 E + BZ05 Indoor Thermohygrometer
Availability: Immediately available
Convector TCH 22 E + BZ05 Indoor Thermohygrometer
Solid direct heating device for clean warmth for temporary and additional heating.
The convector of TCH 22 E series is the perfect solution for an energy-efficient temporary heating or full heating of small or medium-sized rooms with an appealing design. With the convectors of TCH- series you do not have to pay for oil or gas, the only thing you need for application is a socket- set up, that's all!
In order to provide a secure positioning the convectors of the TCH-serie are equipped with big and stable feet. Because of its light weight and the carrying handles the convector can be quicly transported from one place to another.
Via three heating stages ( 750 W, 1.250 W und 2.000 W) the room can be easily, quietly and odorlessly warmed up. Moreover the integrated overheat protection guarantees safe operation, because the convector TCH 22 E switches itself off as soon as the device overheats.
The TCH 22 E has a special feature- switchable turbo- blower for a accelerated air circulation- optimal for quick start of heating of cool rooms or ventilation inserts.
Another practical detail is the Timer for individual daily programming of heating periods from 15 min up to 24 h , which provides the optimal and uncomplicated heating solution.
Benefits of the regular distribution of convector's warmth:
By the convectors of TCH serie the air will be warmed up through electric heated wires and as a consequence the warm air rises up to the ceiling, in that way a natural maelstrom is created, which pull the cold air in the device.
Thus the ciruculation of warm air is created in the whole room, it flows into all corners of the room. The warmth spreads evenly everywhere what prevents the overheating or underheating of individual areas.
As soon as the preset degree of heat is reached , the device switches itself off and when the temperature fall below the preset degree the devices switches itself on.
The frost monitor function- ideal by short-term real estate vacancy or ŕooms, which are not constantly used!
With the stepless thermostat controlled mobile TCH-convectors, you can use the device also in frost monitor operation. Thanks to thermostat the heating device will be activated automatically in order to keep the rooms frost free or to avoid any rapid cooling.
For use as a frost monitor the TCH convectors are suitable not only for lanlords or real estate companies- also private and businesspeople can find the function of keeping the room or garages free from frost very practical.
Especially rooms, winter gardens or cellars, which are not connected to the central heating, in that way can be kept warm.
Few practical benefits of the TCH 22 E:
- Up to 2.000 W heating capacity for clean, condense-free and odourless warmth
- Stepless thermostat control
- Two switches with three different heat settings
- Thermostat-controlled automatic operation
- Frost monitor function
- Energy-efficient operation thanks to automatic switch off when the preset value is reached
- Overheat protection
- Silent heating
- Flexibly applicable as floor-mounted device
- Stable standing- thanks to big adjustable feet
- Big grid for maximale convection
- Practical carrying handles for quick change of place
- Stepless adjustable thermostat - switches the device on and off in order to maintain temperature
Technical details:
- Suitable for rooms up to 24 m²
- Heating performance (Stage 1 / 2 / 3): 750 W / 1.250 W / 2.000 W
- Supply voltage : 230 V / 50 Hz
- Electric supply: CEE 7/7
- Cable length: 1,5 m
- Sound level: -
- Dimensions without feet (L x W x H): 110 x 533 x 355 mm
- Dimensions with feet (L x W x H): 200 x 533 x 390 mm
- Weight: 2,0 kg
- Timer- adjustable between (15 min and 24 h)
- Switchable turbo-blower for accelerated air circulation
- Scope of delivery: heating device, feet, manual instruction
The BZ05 is not just another one of your run-of-the-mill alarm clocks. The BZ05 is a state-of-the-art thermohygrometer that can measure air temperature and relative humidity quickly and reliably and display the readings together with the time and date in large, easy-to-read values. And yes it can also be used as an alarm clock.
There is a wall mount included in the scope of delivery which means that you can decide where you think your BZ05 looks best. In addition there’s also an indicator which can tell you at a glance if the climate values that are currently being measured are within the parameters that are perceived by most people to be comfortable.
Ideal for:
- Living areas: at-a-glance look at all important climate data
- Bed and hotel rooms: alarm clock with added essential indoor climate information
- Offices / workplace: can be used to keep an eye on the room climate and ensure that levels are comfortable and conducive for a working environment
- Spas, massage practices, wellness centres: ensures that temperature and relative humidity remain at levels which patients and visitors perceive to be comfortable
Technical Data:
- Measuring range, air temperature: 0 °C to +50 °C (32 °F to 120 °F)
- Resolution, air temperature: 0.1 °C
- Accuracy, air temperature: ±1 °C (±1.8 °F)
- Measuring range, relative humidity: 10% RH to 90% RH
- Resolution, relative humidity: 1% RH
- Accuracy, relative humidity: max. ±5% RH
- Functions: Minimum and maximum value, date and comfort indicator, alarm function, temperature display in °C and °F
- Dimensions: 108 x 60 x 15 mm
- Weight: 74 g (incl. battery)
Technical data | ||
---|---|---|
General information | ||
Article number | 1.410.000.515 | |
Heating capacity | ||
Level 1 [kW] | 0.75 | |
Level 2 [kW] | 1.25 | |
Level 3 [kW] | 2 | |
Level Max. [kW] | 2 | |
Electrical values | ||
Mains connection | 230 V, 50 Hz | |
Max. power input [W] | 2,000 | |
Nominal current consumption [A] | 8.7 | |
Safety feature | ||
IP type of protection | IPX0 | |
Protection class | I | |
Overheating protection | Available | |
Electric connection | ||
Connection plug | CEE 7/7 | |
Cable length [m] | 1.2 | |
Mobility | ||
Feet | ||
Recessed handles | ||
Dimensions | ||
Length (feet included) [mm] | 160 | |
Width (feet included) [mm] | 520 | |
Height (feet included) [mm] | 390 | |
Weight | ||
(packaging excluded) [kg] | 2.5 |
Equipment, features and functions | ||
---|---|---|
Functions and features | ||
Turbo blower | ||
24 h timer | ||
Frost monitor function | ||
Operating control lamp | ||
Thermostat-controlled automatic operation | ||
Automatic switch-off upon reaching the set value | ||
Auto restart function | ||
Operation | ||
Steplessly adjustable thermostat | ||
Housing design | ||
Sheet steel – coated |
standard equipment
optionally available
not available
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.205.010 | |
Air temperature [°C] | ||
Min. measuring range | Air temperature [°C] | 0 | |
Max. measuring range | Air temperature [°C] | 50 | |
Resolution [°C] | 0.1 | |
Accuracy ± | Air temperature [°C] | 1 | |
Accuracy ± 1 °C - 50 °C [°C] | 1 | |
Air temperature [°F] | ||
Min. measuring range | Air temperature [°F] | 32 | |
Max. measuring range | Air temperature [°F] | 122 | |
Resolution [°F] | 0.1 | |
Accuracy ± | Air temperature [°F] | 1.8 | |
Relative humidity (%) | ||
Min. measuring range | Relative humidity [%] | 10 | |
Max. measuring range | Relative humidity [%] | 90 | |
Resolution | Relative humidity [%] | 1 | |
Accuracy | Relative humidity [%] | 5 | |
Display | ||
LCD | ||
Monochrome | ||
Device control | ||
Push buttons | ||
Housing design | ||
Plastics | ||
Power supply | ||
External (power adapter) | ||
Internal (battery) | 1 x 1.5 V, AAA | |
Ambient conditions | ||
Operation - min. temperature [°C] | 0 | |
Operation - max. temperature [°C] | 50 | |
Operation approx. - max. relative humidity (non-condensing) [%] | 80 | |
Storage - min. temperature [°C] | -20 | |
Storage - max. temperature [°C] | 60 | |
Storage - max. relative humidity (non-condensing) [%] | 80 | |
Dimensions | ||
Length (packaging excluded) [mm] | 108 | |
Width (packaging excluded) [mm] | 15 | |
Height (packaging excluded) [mm] | 60 | |
Weight | ||
(packaging excluded) [kg] | 0.074 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Measuring device | ||
Battery(-ies) | ||
Operating manual | ||
Factory test certificate | ||
Storage case |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Relative humidity [%] | ||
Air temperature [°C] | ||
Air temperature [°F] | ||
Functions and features | ||
Minimum value display | ||
Maximum value display | ||
Switching function °C/°F | ||
Date | ||
Time | ||
Alarm function |
standard equipment
optionally available
not available

Declaration of conformity convector TCH 20 E / TCH 22 E (DE)
TRT-CE-TCH20E-TCH22E-HS-002-DE.pdf (109 KB)

Declaration of conformity convector TCH 20 E / TCH 22 E (INT)
TRT-CE-TCH20E-TCH22E-HS-002-EN.pdf (109 KB)

Operating manual for convector TCH 20 E / TCH 22 E (DE)
TRT-BA-TCH20E-TCH22E-TC-012-DE.pdf (644 KB)

Operating manual for convector TCH 20 E / TCH 22 E (EL)
TRT-BA-TCH20E-TCH22E-TC-012-EL.pdf (642 KB)

Operating manual for convector TCH 20 E / TCH 22 E (EN)
TRT-BA-TCH20E-TCH22E-TC-012-EN.pdf (641 KB)

Operating manual for convector TCH 20 E / TCH 22 E (FR)
TRT-BA-TCH20E-TCH22E-TC-012-FR.pdf (685 KB)

Operating manual for convector TCH 20 E / TCH 22 E (IT)
TRT-BA-TCH20E-TCH22E-TC-012-IT.pdf (637 KB)

Operating manual for convector TCH 20 E / TCH 22 E (NL)
TRT-BA-TCH20E-TCH22E-TC-012-NL.pdf (639 KB)

Operating manual for convector TCH 20 E / TCH 22 E (TR)
TRT-BA-TCH20E-TCH22E-TC-012-TR.pdf (642 KB)